Climatest Symor® benchtop environmental chamber is a desktop type for the smaller specimens in a limited-space laboratory. This benchtop environmental chamber offers the ideal conditions to test the resistance of specimens against extreme temperatures and provides an optimal testing solution with a compact volume of 12L, 22L, and 36L. The benchtop temperature test chamber has become the best seller in laboratories and research institutes.
Model: TGDW-36
Capacity: 36L
Shelf: 1pc
Color: Off-white
Interior dimension: 400×300×300 mm
Exterior dimension: 640×730×970 mm
Description
Climatest Symor® is a benchtop environmental chamber manufacturer and supplier in China, this test chamber is small enough to be placed on the benchtop, and provides accurate, precise PID control of temperatures, with advantages of easy installation and convenient operation, the user can perform temperature tests with a range of -40°C~+130°C.
Specification
Model | TGDW-12 | TGDW-22 | TGDW-36 |
Interior Dimension(W*D*H) | 310×230×200 mm | 320×250×250 mm | 400×300×300 mm |
Exterior Dimension(W*D*H) | 500×540×650 mm | 520×560×730 mm | 640×730×970 mm |
Temperature Range | Model A :-20°C~+130°C Model B: -40°C~+130°C | ||
Temperature Fluctuation | ≤±0.5°C | ||
Temperature Bias | ≤±1.0°C | ||
Temperature Uniformity | ≤1.5°C | ||
Heating Rate | +25℃~+130℃≤50 minutes(unload) | ||
Cooling Rate | +25℃~-40℃≤45 minutes(unload) | ||
Interior Material | SUS#304 brushed stainless steel | ||
Exterior Material | Reinforced Steel plate with electrostatic spraying | ||
Insulation | Superfine fiberglass wool/polyurethane foam | ||
Controller | 7” Programmable touchscreen controller | ||
Circulation System | Low-noise, high temperature resistant motors, long axis and stainless steel multi-leaf type centrifuge fan | ||
Heating System | NiCr heater, independent system | ||
Refrigeration System | France "TECUMSEH" Refrigeration Compressors, air cooling | ||
Power Supply | AC110V/220V/AC230V·50HZ/60HZ |
Safety protection:
· Independent temperature limiter
· Over-heat, over-current and over-pressure protection of compressor.
· Over-temperature protection, overheat of fan and motor, phase failure/reverse, and timing.
· Leakage and outage protection, overload fusing protection, audio signal alarm, power leakage, and overload protection
Key Features
▸Compact size: Small footprint, suitable for placement on a desktop or workbench.
▸Temperature Range: Simulates a temperature range of -40°C to 150°C (-40°F to 302°F).
▸Programmable control: Programmable control can set specific temperature profiles and test cycles.
▸Fast temperature change rate: capable of rapid temperature changes to simulate different environmental conditions.
▸Uniform temperature distribution: Ensure consistent temperature throughout the chamber for accurate test results.
Benefits
·Easy installation
·Precise temperature control in small chamber
·Desktop type designed for limited space laboratory
·Over-temperature limiter
·Programmable LCD touch screen controller
·Record 365 days history data
·Temperature & humidity realtime and history profile display
·RS485 computer interface for data download
Application of benchtop environmental chamber
▸Material testing:
. Thermal Expansion: The study of the thermal expansion and contraction properties of materials.
. Durability testing: Evaluates the durability of materials and products under repeated temperature cycles.
▸Electronic testing:
. Component Testing: Stress testing electronic components such as semiconductors, circuit boards, and sensors under various temperature conditions.
. Reliability testing: Evaluates the reliability and performance of electronic equipment when exposed to extreme temperatures.
▸Quality Control: Used in industries to ensure products meet specific environmental standards before reaching the market.
▸Scientific Research: Used in laboratories to study the effects of environmental conditions on biological samples, chemical reactions, and materials.
How to set fix value and programs?
▸Fix value setting: 85°C
▸Programs setting: Heat up to 85°C, constant 5 hours @85°C, cool down to 30°C, constant 2 hours@30°C, cool down to 0°C, constant 6 hours @0°C, cool down to -20°C, constant 2 hours@-20°C, then take out @23°C.
Benefits from the benchtop environmental chamber
▸Space Efficiency: Takes up less space than larger chambers, freeing up valuable workspace.
▸Portability: Light weight, can be easily moved to different locations.
▸Cost-effective: Consumes less energy and requires less maintenance, resulting in lower operating expenses.
▸Accuracy and Control: Provides precise control over temperature range, ensuring reliable and consistent testing conditions.
▸User-friendly design: Simple controls and display make setup and operation easy.
Calibration
Each Climatest Symor® benchtop environmental chamber comes with a calibration certificate calibrated by SGS, an ISO17025 accredited laboratory. We strictly control the performance and quality of our desktop temperature test chambers. Our quality control tracks the entire process from production to commissioning. At the same time, we ask the SGS laboratory to calibrate again before shipping, to ensure that customers are satisfied with the machine and can put it into use immediately after receiving it.
The temperature uniformity is controlled within 1.5°C, bias is controlled within ±1.0°C, and the machine performs very well with low maintenance and operation costs.
How to pack benchtop environmental chambers?
1. Wrap thin film onto the whole chamber for waterproof and dustproof purpose.
2. Bind bubble foam on temperature test chamber tightly, and then cover the machine with a big plastic bag.
3. Put it into a reinforced polywood case with pallet.
This package is firm enough to withstand bumpy sea and railway transportation, and ensure the product is delivered to customers smoothly.
Frequently Asked Questions and Answers
Q: How much does a benchtop environmental chamber cost?
A: If you are interested in these benchtop chambers, and want to know the prices, please reach us via email at sales@climatechambers.com to get a formal quotation.
Q: What is the noise level during operation?
A: 65 dB.
Q: What is the lead time for delivery?
A: 7 days for standard models, and pls check with us for customized models.
Q: How do I maintain a benchtop environmental chamber ?
A: The chamber is low maintenance, the regular maintenance includes cleaning the working area after each test, and plugging off the power supply if idle for a long time, details pls refer to our user manual.