Humidity Control Storage Cabinet

Humidity control storage cabinet provides fast dehumidifying storage environment for moisture sensitive devices, the humidity control storage cabinet is not only for drying storage, but also fast moisture removal, dust proof and anti-static (ESD) protection for your electronic components.

Model: TDA718F
Capacity: 718L
Humidity: 20%-60%RH adjustable
Recovery time: Max. 30 min after open door 30 seconds then closed. (Ambient 25℃ 60%RH)
Shelves: 5pcs, height adjustable
Color: Dark blue, ESD safe
Interior dimension: W596*D682*H1723 MM
Exterior dimension: W598*D710*H1910 MM

Send Inquiry

Product Description

Description

Climatest Symor® humidity control storage cabinet or low humidity storage cabinet, keeps precise humidity control with patented technology, this auto dry cabinet is suitable for storing MSD, like printed circuit boards (PCB), plates, optical fibers, cassettes, optical fibers, integrated circuits, chips and laboratory specimen.



Specification

Mode# with F: ESD function, Dark Blue color.
Mode# without F: No ESD function, off white color

Model

Capacity

Interior Dimension

(W×D×H,mm)

Exterior Dimension

(W×D×H,mm)

Average Power (W)

Gross Weight (KG)

Max. Load/shelf (KG)

TDA98

98L

446*372*598

448*400*688

8

31

50

TDA98F

98L

446*372*598

448*400*688

8

31

50

TDA160

160L

446*422*848

448*450*1010

10

43

50

TDA160F

160L

446*422*848

448*450*1010

10

43

50

TDA240

240L

596*372*1148

598*400*1310

10

57

50

TDA240F

240L

596*372*1148

598*400*1310

10

57

50

TDA320

320L

898*422*848

900*450*1010

10

70

80

TDA320F

320L

898*422*848

900*450*1010

10

70

80

TDA435

435L

898*572*848

900*600*1010

10

82

80

TDA435F

435L

898*572*848

900*600*1010

10

82

80

TDA540

540L

596*682*1298

598*710*1465

10

95

80

TDA540F

540L

596*682*1298

598*710*1465

10

95

80

TDA718

718L

596*682*1723

598*710*1910

15

105

80

TDA718F

718L

596*682*1723

598*710*1910

15

105

80

TDA870

870L

898*572*1698

900*600*1890

15

130

100

TDA870F

870L

898*572*1698

900*600*1890

15

130

100

TDA1436-4

1436L

1198*682*1723

1200*710*1910

25

189

100

TDA1436F-4

1436L

1198*682*1723

1200*710*1910

25

189

100

TDA1436-6

1436L

1198*682*1723

1200*710*1910

25

189

100

TDA1436F-6

1436L

1198*682*1723

1200*710*1910

25

189

100


Feature

·Adopts Switzerland original imported humidity & temperature sensor.
-This ensures high precision in use, moreover, the humidity control storage cabinet has memory function, no need to re-set after power interrupted.

·Made by 1.2mm thickness galvanized steel, with USA DuPont anti-static powder spraying.
-Solid structure, excellent load-bearing, surface treatment with 18 powder spraying processes, the static resistance value meets 106 -108Ω.

·Equipped with over-humidity alarm + door open alarm , and data logging system.
-Once the interior humidity exceeds the setting value, or the door is open, it will immediately alarm with sound and light, to remind the operator.

·Powerful dry module with +15 years projected lifespan.
- The humidity control storage cabinet adopts multi-porous molecular sieve as desiccant, it can be regenerated automatically, no consumables and no replacement needed.

·Excellent air-tightness performance
-The whole dry cabinet adopts the pressurized lock to minimize the possibility of moisture infiltration.


What is 40℃ humidity control storage cabinet?

Climatest Symor® humidity control storage cabinet is utilized to control humidity within 20%RH-60%RH, any humidity point in this range can be set freely, the humidity control storage cabinet adopts the auto dehumidifying technology.
The dry unit is the heart of an electronic dry cabinet, dry air cabinet, it is made by synthetic desiccant, which can be generated automatically, and maintenance free, this synthetic desiccant lifespan is + 15 years, no need replacement, no cooling drops, no desiccant bags, no nitrogen needed, the whole dehumidifying process is silent and environmental.
The dry unit uses the latest synthetic desiccant and shape memory alloy inside, even after power failure, the synthetic desiccant still continue to absorb humidity, the interior humidity should not rise more than 10%RH within 24 hours.

Dry cabinet for electronics adopts high accuracy Switzerland imported RH and temperature sensor, the sensor automatically controls the refreshing and recycling of the synthetic desiccant, with 2% accuracy.


Why is humidity control storage cabinet necessary in SMT process?

With the increasing application of humidity control storage cabinet, humidity controlled storage of electronic components becomes essential in the electronic manufacturing and assembly industry. The electronic components have been marked with moisture sensitive level (MSL) before ex-factory, IPC standard specifies the humidity requirement for integrated circuits under corresponding MSL, at present, there are two main recommendation in the standard, that are ><5%RH and ><10%RH storage in a dehumidify dry storage cabinet, or dry box. "For the unpacked MSD, when the exposure time does not exceed 72 hours, it can be stored under the specified humidity (such as below 10% RH or below 5% RH) for 5 times or 10 times longer in a humidity control storage cabinet, the floor life can be recovered.”

Normal storage

 Reflow process

Moisture in the ambient penetrates into the packages.

During heating, the water steam pressure increases, that separates the die and resin.

The water steam continues to expand under heating, blowing up the packages.

The water steam breaks the packages, which causes micro-cracking.


20%-60%RH Series dehumidifying speed:

(Ambient 25 degree C, humidity 60%RH)


The difference between electronic dry cabinet and nitrogen cabinet:

1.The nitrogen cabinet is filled with nitrogen gas to squeeze out the oxygen inside cabinet, so as to form an inert gas protection environment, this way can prevent the wafers, IC chips, and LED chips from being oxidized. Nitrogen cabinet depends on the nitrogen purge to meet low humidity and anti-oxidization storage, the nitrogen purity is suggested to be >99%, nitrogen cabinet is commonly used in microelectronics, semiconductor industries The electronic dry cabinet is auto dry cabinet, dehumidifying dry storage cabinet, which can absorb moisture and discharge to the outside, to form a low humidity storage environment, it do has humidity control ability. 2.The nitrogen cabinet uses the inert gas to create an oxygen-free or low-oxygen environment, the products put into the nitrogen cabinet are basically moisture-proof packaging, oxidation is difficult to occur. The electronic dry cabinet can only control humidity, no anti-oxidization function,the oxygen content is almost same as the ambient environment.


Characteristics of humidity control storage cabinet

Independent modular design: This humidity control storage cabinet adopts a patented modular design, the temperature & humidity display, the control system, heating module, dry modules can be quickly replaced, maintenance is simple, this significantly improves maintenance efficiency.
Environmental design: The whole humidity control storage cabinet does not produce waste to pollute the environment. This model is designed for long-term use, if the main structure of the machine body is complete, non-destructive, only need to periodically check and replace the faulty module, it can be used forever, this is the latest green design that conforms to environmental protection.
Easy operation: There is no complicated settings, and personnel do not need training, the machine only needs plug in, it can operate fully automatically. It is an efficient industrial-grade humidity control storage cabinet. It not only saves you personnel training cost, but also greatly improves the production efficiency of the factory.
Calibration reminder: The drift of sensors influence the humidity control storage cabinet accuracy. In order to comply with the ISO regulation, the calibration expiration reminding function is offered in this model. When the sensor runs over the pre-set days, the decimal point in the controller will flash to remind the user, this function effectively save manpower.



For more details about humidity control storage cabinet, pls visit our website www.climatestsymor.com or directly send emails to sales@climatestsymor.com, we will get you back at quickest time, welcome for possible collaboration.








Hot Tags: Humidity Control Storage Cabinet, Manufacturers, Suppliers, China, Made in China, Price, Factory